Automatic Flasher_Streetlight/Security Light Monitoring/Control System
General Configuration of the Streetlight/Security Light Monitoring and Control System
Main Function and Feature by Device
Central Control System [KIS- 5000]
- 24-hour integrated control and real-time monitoring of street lamp/security light
- Light on/off deviation, Alternative lighting, Remote setting of operation data
- GIS-based facility DB management and map marking
- Real-time monitoring of operation status and error status, Map coloring
- DB management for Facility management, Daily work journal, Work sheet, Filed complaints
- Real-time text and voice notification of error to Administrator
- 24-hour auto receiving and processing of complaint and remote notification and replay to Administrator
- Internet-based multi PC link and auto synchronization for multiple Administrators
- DB and Map synchronization through Active Sync with PDA
- Communication server for u-City social welfare security services
Security Light Relay Communicator [KIS- 1000T]
- Security light monitoring/control using CDMA communication + wireless low-output communication
- Real-time remote control, surveillance, collection and notification
- Collection and notification of operation/error status of up to 256 Security lights
- Light on/off deviation, Night-time light-off, Remote setting of various operation data
- Self visual calibration and management, Auto synchronization of security lights
- Duplicated built-in self-security light monitoring flasher function
- On-site manual on/off control and check
- Built-in Korean LCD and manual operation keys
- Power failure monitoring and notification with high capacity battery
- Added function of social welfare security service
Street Lamp Surveillance Flasher [KIS- 2000C]
- Security lamp monitoring/control using CDMA communication + wireless low-output communication
- 24-hour real-time remote control, surveillance, collection and notification
- Light on/off deviation, Alternative lighting, Remote setting of various operation data
- Notification of on/off status, power failure, electric leakage on the line, branch short-circuit
- Measurement and notification of voltage, leakage current and power value by branch line
- Self storage and LED display of operation/error status
- On-site control and check using manual operation key and PDA
- Surveillance of operation of individual street lamp, lamp/stabilizer error, electric leakage on the light pole
- Notification of self-diagnosis and real-time LCD display of current event
- Configured with high voltage surge protection circuit
- Surveillance and control of up to 8 branches, 256 street lamps
- Added function of u-City social welfare security service
Security Light Surveillance Flasher [KIS- 1000C/CD]
- Security light monitoring/control using wireless low-output communication
- Double safe control (built-in electronic function)
- Surveillance and notification of abnormal operation, lamp/stabilizer error, electric leakage, power failure
- Light on/off deviation, Visibility, Remote setting of various operation data
- Breaking the stabilizer for protection in the event of lamp failure (preventing no-load power loss)
- On-site manual control and built-in Korean LCD and manual operation keys
- Built-in dynamic auto connection relay (ACL method)
- Easy installation and maintenance with dual internal case structure
- Double locking and embedded ELB structure to prevent safety accident
- Added function of u-City social welfare security service
Wireless Light Pole Surveillance Device [KIS- 2000WS/WD]
- Individual control/maintenance/surveillance of street lamp using wireless low-output communication
- ON/OFF status of individual light pole, Lamp/stabilizer failure, Electric leakage, Communication status
- Breaking non-load power loss and protecting stabilizer in the event of lamp failure
- Individual ON/OFF function for on-site maintenance and check
- Built-in dynamic auto connection relay (ACL method)
- Applicability: for 1-lamp and 2-lamp
- Added function of u-City social welfare security service